Problem
A European dosing-equipment maker saw hardened-steel plungers score within months on abrasive media.
Solution
Mirror-lapped Y-TZP zirconia plunger-sleeve pairs, clearance held at micron level.
Result
Service life roughly quadrupled; dosing drift eliminated between maintenance intervals.